hpialarms(1) - Linux man page

Name

hpialarms - A openhpi sample application that shows "Alarm Control" management instruments

Synopsis

hpialarms [-a -b -c -i -m -n -p -o -x]

Description

hpialarms walks the RPT (Resource Present Table) for resouces that have "Alarm Control" management instruments ( SAHPI_CTRL_LED ).

Options

-c1  sets Critical Alarm on
-c0  sets Critical Alarm off
-m1  sets Major Alarm on
-m0  sets Major Alarm off
-n1  sets Minor Alarm on
-n0  sets Minor Alarm off
-p1  sets Power Alarm on
-p0  sets Power Alarm off
-i5  sets Chassis ID on for 5 sec
-i0  sets Chassis ID off
-a1  sets Disk A fault on
-a0  sets Disk A fault off
-b1  sets Disk B fault on
-b0  sets Disk B fault off
-d[byte] sets raw Alarm byte
-o   sets all Alarms off
-x   show eXtra debug messages

Sample Output

hpialarmpanel ver 0.6
RptInfo: UpdateCount = 5, UpdateTime = 8a2dc6c0
rptentry[0] resourceid=1 tag: Mullins
RDR[45]: ctltype=2:1 oem=0  Chassis Identify Control
RDR[48]: ctltype=0:1 oem=10 Front Panel Power Alarm LED         state = off
RDR[51]: ctltype=0:1 oem=13 Front Panel Minor Alarm LED         state = ON
RDR[46]: ctltype=0:0 oem=0  Cold Reset Control
RDR[49]: ctltype=0:1 oem=11 Front Panel Critical Alarm LED      state = off
RDR[50]: ctltype=0:1 oem=12 Front Panel Major Alarm LED         state = off

See Also

Authors

Authors of this man page:

Peter D Phan (pdphan@users.sourceforge.net)